Probe

The 1" (25mm) Diameter, 10" long Probe can be used with a 2:1 Booster to achieve a 100µm amplitude. This probe is used for processing 1-10L volumes.

Note: Processing volumes are application specific. Variables including sample viscosity and concentration can affect the processing volume for a specific probe size.
Additional stirring may be helpful for certain applications.

Probe
 

Part No.
630-0697


Sound Enclosure

Ultrasonic processing produces high pitched noise, which originates from the vessel walls and the liquid surface. The sound enclosure reduces the noise to comfortable levels.  Access ports are available on both sides and the top of the enclosure for use with the flow cell.  A stand with clamp must be ordered separately.

OUTER DIMENSIONS
(H x W x D) 38” x 18” x 173/4" (965 x 457 x 450mm)

INNER DIMENSIONS
(H x W x D) 36” x 16” x 163/4" (914 x 406 x 425mm)

Sound Enclosure
 

PART NO.
830-00474


Support Stand and Clamp

Securely support the VCX1500 Converter and probe assembly with a metal holder on a 51/2" x 9” cast-iron base with 1/2" diameter rod.

Stand and Clamp
 

Part No.
830-00461


Flow Cell

The flow cell enables continuous processing of 5L or more. The throughput rate depends on many variables including viscosity and desired degree of processing. The flow cell is recommended for the treatment of low viscosity samples which do not require extended exposure to ultrasonics. For optimum performance, when working on a flow through basis, pre-mixing the sample with a mechanical stirrer is recommended. Multiple units can be used in series to reduce processing time and/or maintain higher flow rates.

The process fluid is pumped into the flow cell through the inlet at the bottom. As the sample passes through the cavitation field at the tip of the flow cell probe, it is processed. The processed liquid exits the unit through an outlet port. The degree of processing can be controlled by adjusting the intensity of sonication as well as flow rate.

The 1" (25mm) high efficiency probe is included with the flow cell. All process connections are sanitary and the unit is easily disassembled for cleaning. All wetted parts are autoclavable. The flow cell is water jacketed to assist in cooling the sample fluid during processing. The chiller PART NO. 830-00906 is recommended for use when cooling the water jacket on the flow cell.

Use of the sound enclosure (part no. 830-00474) is always advised.

1500 WATT ULTRASONIC PROCESSOR, CONVERTER, BOOSTER, PROBE, HIGH VOLUME FLOW CELL
Flow Cell
 

Part No.
VCX 1500HV

 
CROSS SECTION OF FLOW CELL
CROSS SECTION OF FLOW CELL
 
FLOW CELL ASSEMBLY
FLOW CELL ASSEMBLY

Part No.
630-0549

 
REPLACEMENT PROBE
REPLACEMENT PROBE

Part No.
630-0625

Flow Cell Specifications

Material

316 stainless steel

Height

17" (432mm)

Width

16" (406mm)

Weight

12 lbs. (5.5 kg)

Operating pressure

Up to 100 psi

Internal volume w/probe

400mL

Product/Coolant Connectors

1/2" (13 mm) sanitary fittings


General Accessories
Temperature Probe
Temperature Probe

Enables sample temperature monitoring from 1-100ºC.

Part No.
830-00060

CONVERTER
Converter

Replacement 20kHz converter for the VCX1500.

Part No.
CV00294

CONVERTER CABLE
HEAVY DUTY SUPPORT ASSEMBLY

Replacement converter cable for VCX1500.

Part No.
201-0106

BOOSTER
BOOSTER

When connected between the converter and the probe, the booster acts as a mechanical amplifier that increases the amplitude of vibration by a factor of 2.

Part No.
BHN294T21

WRENCH
WRENCH

Replacement pin spanner wrench. Two wrenches are required.

Part No.
888-00054

REPLACEMENT PROBE FOR DISCONTINUED
FLOW CELL
REPLACEMENT PROBE

1" (25mm) Diameter, 10" long high efficiency probe with o-ring groove. This probe can be used to process 500mL -1L volumes or with the previous model flow cell. A 2:1 booster is recommended for more efficient sample processing.

Part No.
630-0617